Product Improvements
Find the most recently published product improvement updates listed here by publish date.
504338098R Alternator- Product Improvement
Problem: Dead battery due to alternator not charging. Solution Date: In Review- final solution not found Failure Mode: Alternator not charging Root Cause: Brush wire gets frayed if the brush is allowed to extend beyond its original...
JR4076442 Fuel Pump- Product Improvement
Arrows are showing the fuel leak locations that were found during the investigation.Problem: Pump Leaking Failure Mode: Excessive Fuel Leakage Root Cause: Operators were not acheiving O.E. torque specifications at the joint between the...
8097812R Cursor 9L- Product Improvement
Solution Date: 5/30/2018 Serial Number Break: 181500001 Failure Mode: Head Gasket Leaks Root Cause: Top deck surface finish was to rough or smooth along with potential peaks and valleys that were out of spec Improper RA or RZ surface...