Print Friendly, PDF & Email

5802855463 Denox 2.2+ module

Solution Date: 12/1/2022      Serial Number Break: 223360001

Problem:  Engine can derate and go into limp mode or show  Fault Codes 19077, 193337

Root Cause: The flutter membrane in the older version modules would harden and not operate properly in below freezing temperatures.

Solution: The 2.2+ modules were upgraded with a new flutter membrane design and material composition that will prevent flow restrictions.

5802855463R_PI_membrane_new

Flutter membrane – New version

5802855463R_pi_membrane_old

Flutter membrane- Old version

@media print { /* Reset the base styles for table content */ table, table tr, table td, table th, .dvmd_table_maker .dvmd_tm_table, .dvmd_table_maker .dvmd_tm_trow, .dvmd_table_maker .dvmd_tm_tcell, .dvmd_table_maker .dvmd_tm_cdata { -webkit-text-size-adjust: 100% !important; -webkit-tap-highlight-color: rgba(0,0,0,0) !important; text-align: left !important; color: #222 !important; /* Preserving text color */ font-family: Arial, Helvetica, sans-serif !important; /* Ensuring the font family is maintained */ font-size: 16px !important; /* Ensuring the font size is preserved */ direction: ltr !important; box-sizing: border-box !important; box-shadow: none !important; /* Removing any box shadows */ } }